Amongst different brands, Accure is one of them which is popular UPS in India. It is known for its high performance, different models and small footprints.
- Line Interactive UPS with AVR
- Ratings: 650VA / 1 KVA / 1500 VA / 2000 VA
- 1 Ph Input / 1Ph Output
- Battery: 1of 12V OR 2 Nos. of 12V depending upon Model.
The product is available in following range
- 650VA
- 1 KVA
- 1.5 KVA
- 2 KVA
650VA
| Model |
Battery |
Nos. |
Recommended Load |
Back Up time (On recommended load) |
| FA65IBS |
12V 7 Ah |
1 |
1 Desktop PC (std config.) |
10 - 15 min. |
| FA65IB |
12V 7 Ah |
2 |
2 PCs with LCD monitors |
20 - 30 min. |
| FA65IBH |
12V 7 Ah |
4 |
2 PCs with LCD Monitors |
40 - 60 Min |
| FA65 EB1 |
12V26Ah |
2 |
2 PCs with LCD Monitors |
~ 2 Hrs. |
1000 VA
| Model |
Battery |
Nos. |
Recommended Load |
Back Up time (On recommended load) |
| FA100IB |
12V 7 Ah |
2 |
2 PCS (Std Config.) |
20 - 30 Min. |
| FA100IBH |
12V 7 Ah |
4 |
2 PCs ( Std Config.) |
40 - 60 Min. |
| FA100EB1 |
12V 26 Ah |
2 |
3 PCs with LCD Monitors |
~ 80 Min. |
| FA 100 EB2 |
12V 42 Ah |
2 |
3 PCs with LCD Monitors |
~ 2 Hrs. |
1500 VA
| Model |
Battery |
Nos. |
Recommended Load |
Back Up time (On recommended load) |
| FA150EB1 |
12V 26 Ah |
2 |
4 PCs (Std. config.) |
40- 60 Min. |
| FA150EB2 |
12V 42 Ah |
2 |
4 PCs (Std. config.) |
60 - 80 Min. |
| FA150EB3 |
12V 65 Ah |
2 |
4 PCs (Std. config.) |
2 Hrs. |
| FA150E101 |
12V 65 Ah |
2 |
4 PCs (Std. config.) |
3 Hrs. |
| FA150E102 |
12V 100Ah |
2 |
4 PCs( Std. Config.) |
~4-5 Hrs. |
2000 VA
| Model |
Battery |
Nos. |
Recommended Load |
Back Up time (On recommended load) |
| FA200EB1 |
12V 26 Ah |
2 |
5 PCs (Std. Config.) |
30 Min. |
| FA200EB2 |
12V 42 Ah |
2 |
5 PCs (Std. Config.) |
45 Min. |
| FA200E101 |
12V 65 Ah |
2 |
5 PCs (Std. Config.) |
100 Min. |
| FA200E102 |
12V 100Ah |
2 |
5 PCs (Std. Config.) |
150 Min.
|
Applications:
- Small Computer Networks
- Home Computers
- Small Offices
- Retail showrooms
Salient Features
- Line Interactive- Ultra fast switching due to synchronized transfer from mains to Inverter and Inverter to Mains.
- Microprocessor Based, reduces component count to increase reliability, simplify servicing.
- Wide Input Voltage Range, ensures UPS runs on mains voltage even at low input voltage without discharging batteries.
- Short Circuit, Over Load protection provides capability to withstand fluctuating load and accidental short circuit in power line.
- Battery Deep discharge protection, Off-Mode charging and "Advanced Battery Management" program to enhance life of battery.
- EMI/RFI/Lightning/SURGE and Spike protection.
- Serial communication port / SNMP (Optional) to enable monitor and control through web.
Key Technical Specifications
| Mains Voltage |
220 V - 1 Ph, |
| Input power factor |
0.99 (mains Mode) |
| Voltage range |
150 to 270 V |
| Frequency Range |
46 to 54 Hz |
| Output Voltage |
220 V +/- 8% |
| Dynamic Voltage for 0-100% Load change |
+/- 2% max. |
Frequency Precision (on Inverter) |
0.2% |
| Crest Factor |
3: 1 |
| Overload Capacity upto 110 % |
For continuous. |
| > 110% |
For 10 Min. |
| Efficiency |
>95 % ( full Load) |
|